RECUTECH Tips and tricks

Published on 8. December 2021

What might you be interested in?

Here are some tips and tricks collected from the Client Zone on our website:

We are pleased to announce the next step in improving our manufacturing expertise. Our largest Combi units CXS +81 and +95 are now available up to 600 mm in one piece!

Recutech counter-flow heat exchangers dimensions

 

X

Y

Z

 

 

X

Y

Z

REK/REP +17

397

172

150 – 1000

 

RSF+16

366

366

100 – 600

REK/REP +23

455

230

150 – 1000

 

RSP+16

366

366

100 – 600

REK/REC/REP +27

496

271

150 – 1000

 

RSP+30

461

232

100 – 600

REK/REC +31

537

312

150 – 1000

 

 

 

 

 

REK/REC +39

619

394

150 – 1000

 

CXS+39

1034

809

200 – 900

REK/REC +53

758

533

150 – 1000

 

CXS+53

1313

1088

200 – 900

REK/REC +67

599

674

150 – 1000

 

CXS+67

1594

1369

200 – 900

REK/REC +81

1040

815

150 – 1000

 

CXS+81

1877

1652

200 – 600

REK/REC +95

1182

957

150 – 1000

 

CXS+95

2167

1942

200 – 600

Installation

The heat exchanger can be installed in the unit in any position:

A – wide tray installation, a 3° – 5° exchanger slope is recommended for condensate drainage

B – narrow tray installation, this position is allowed only if the entire weight of the exchanger does not rest on the narrow tray

C – installation on the face surface, a 3° – 5° exchanger slope is recommended for condensate drainage

Both faces of the heat exchanger must be firmly fixed and secured over the entire area so that they do not bend in the air flow.

Operating conditions

 

Aluminum – REK / REC

Plastic – RSF / RSP / REP

Operating temperatures

-40°C to +80°C

-20°C to +60°C

Maximum recommended flow

3 m/s

3 m/s

Length

150 – 1000 mm

100 – 600 mm

Maximum pressure difference

800 Pa

800 Pa

Anti-Fire solution (AF)

Up to 120°C

We recommend using a heat exchanger with a balanced ratio between the outlet and inlet, or with a maximum imbalance of +/- 50%.

Recutech product coding

 

REK+53-557-24-CXS-EP

RSF+16-312-H-T-29

-BY162-14-B-EP

Size of heat exchanger

REK+53

RSF+16

Length

557

312

Plate distance

-24

-29

Combi

-CXS

Epoxy

-EP

-EP

Anti-fire

-AF

T-profile

-T / -F

Bypass length

BY162

Bypass open – closed sides

14 / 23

Bypass hem

A / B

Maintenance and cleaning

If  filters,  approved  by  the  ventilation  unit  manufacturer,  are  used  and  regularly replaced,  the  heat  exchanger  doesn‘t  require  special  maintenance.  If  the  heat exchanger still gets dirty, carefully remove the heat exchanger and clean it with a soft brush. It is possible to use a brush attachment for a vacuum cleaner and vacuum the dirt. Blow out the cleaned heat exchanger with air (from a vacuum cleaner) so that there is no fine dust in it. If necessary, the heat exchanger can be treated with a disinfectant or antibacterial agent, which is suitable for cleaning and disinfecting aluminum and plastic. Allow the heat exchanger to dry thoroughly before inserting it into the unit.

Important:  For  cleaning  do  not  use  sharp  tools  neither  hard  brushes.  Beware  of pressure washing. There is a risk of permanent damage to the heat exchanger!

.STEP in Client Zone